Movement model evaluation — v1.2

The selected extension is an adaptive temporal trajectory layer over the existing 14-DOF rigid-body inverse-kinematics fit. v1.3 adds bounded solver steps, per-frame observation-fit constraints and missing-ancestor measurement masks; see ENGINE-AUDIT.md. This is a local implementation, not an implementation of any of the learned models below. The app interface is unchanged.

Alternatives considered

Approach Useful property Decision for this app
OpenSim-style weighted IK Explicit marker and coordinate errors with a subject-specific skeleton Retain the current planar geometric fit as the baseline
KinePose temporal IK Optimizes pose and temporal terms in a biomechanically constrained chain Supports exploring temporal constraints; a full sequence optimizer is a future alternative, not what ships here
MediaPipe world landmarks Already exposes image and 3D world landmarks Retain as pose-source information; inferred depth does not establish calibrated biomechanical accuracy
VideoPose3D Learned temporal convolutions lift 2D trajectories to 3D Requires landmark mapping, browser inference packaging and running-specific evaluation before integration
MHFormer Multiple hypotheses and temporal attention address 3D pose ambiguity Promising research candidate; requires weights, deployment work and a running validation dataset

The last column is an engineering assessment, not a comparative accuracy claim. No neural model weights were downloaded or evaluated in this change. Adding degrees of freedom to a single side-view recording would add depth assumptions that the present synthetic 2D oracle cannot validate.

What ships

Each generalized-coordinate trajectory is fitted in centered local cubic windows with three Cauchy reweighting passes. Angles are unwrapped before fitting. Windows use actual timestamps, require at least seven observations, leave boundaries unchanged and never cross missing samples or timestamp discontinuities. The forward-kinematics reconstruction retains rigid lengths. Velocities and mechanical work are recomputed from the resulting trajectories. Per-landmark and overall residuals are recomputed after reconstruction.

Automatic selection requires at least 100 fps and an original median IK residual of 0.4–3% of leg length. Radius is 30 ms below 1.5% residual and 45 ms above it. These are engineering thresholds chosen on synthetic examples, not physiological constants. Clean fits bypass the layer. Fits above 3% retain the poor-fit behavior. fitKinematicModel(cond, { temporal: false }) provides the reproducible baseline; temporal: true forces the candidate at supported frame rates for experiments.

Paired benchmark

Run npm run benchmark:model. Sixty clips: five deterministic seeds, three frame rates, four noise levels; two knees per clip. Each clip lasts four seconds and cadence varies with seed. Reference: direct knee angles from the conditioned, noise-free rigid synthetic runner. This reference includes the conditioning pipeline and does not validate camera, pose-estimator or real-world errors.

fps Landmark noise / leg length Framewise knee RMS (°) Adaptive knee RMS (°)
60 0% 0.198 0.198
60 1% 1.271 1.271
60 2% 2.514 2.514
60 4% 5.132 5.132
120 0% 0.188 0.188
120 1% 0.848 0.827
120 2% 1.725 1.682
120 4% 3.386 3.087
240 0% 0.189 0.189
240 1% 0.637 0.637
240 2% 1.258 1.213
240 4% 2.479 2.255

An initial fixed 60 ms radius was rejected: on three 120 fps examples it added about 1.30° RMS difference to clean knee trajectories despite helping at 4% noise. The adaptive model therefore bypasses clean fits and uses shorter windows. In the initial v1.2 run on this machine, the additional processing for noisy four-second clips was about 40–190 ms at 120–240 fps; this excludes video decoding and pose inference. The additional v1.3 safeguards add computation; use the benchmark’s current runtime output rather than interpreting this original timing as a v1.3 performance claim.

Limits: this is offline temporal smoothing, not a 3D model, force estimator or trained gait prior. Synthetic knee error improvements do not establish improved event timing, all-joint accuracy or mechanical-work accuracy on real runners. The next meaningful validation needs synchronized video and reference motion capture, including occlusions, fast cadence changes and varied camera angles.